Principle of
the CMS50QA Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection
Technology is adopted in accordance with Capacity Pulse Scanning & Recording
Technology,the Pulse Oximeter can be used in measuring the pulse oxygen
saturation and pulse rate through finger.The product is suitable for being used
in family, hospital, oxygen bar, community healthcare, physical care in sports
(It can be used before or after doing sports, and it is not recommended to use
the device during the process of having sport) and etc
Major Features
- Integrated with
SpO2 probe and processing display module
- Small in volume,
light in weight and convenient in carrying
- Operation of the
product is simple ,low power consumption
- SpO2 value
display
- Pulse rate value
display, bar graph display
- A pulse rate
sound indication
- With measured
data overruns limits and low-voltage alarm function
- Low-voltage
indication: low-voltage indicator appears before working abnormally which is due
to low-voltage, and with alarm function
- Small
appearance, more fit for children
Main
performance
- Display Mode:
Segment LCD display
- SpO2 Measuring
Range:0%~100%, (the resolution is 1%).
- Accuracy:70%~100%:±2%
,Below 70% unspecified.
- PR Measuring
Range:30bpm~250bpm, (the resolution is 1bpm)
- Accuracy:±2bpm
or ±2% (select larger)
- Measurement
Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly
when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm
or ±2% (select larger).
- Resistance to
surrounding light: The deviation between the value measured in the condition of
man-made light or indoor natural light and that of darkroom is less than
±1%.
- Power
Consumption:less than 70mA
- Voltage:DC
3.6V~4.2V
- Power
Supply:Voltage 3.6 rechargeable lithium battery × 1
- Battery working
hour:The theoretical number is 10 hours
- Battery working
life:Charge and discharge no less than 300 times.
- Safety
Type:Interior Battery, BF Type
Accessories
Sell in
standard
- a hanging
rope
- a user
manual
- One rechargeable
buttony lithium battery
- Charge
accessories: One power adapter, one charger, one data line
Physical Identity
Dimension:46(L) × 40(W) ×
29(H) mm Weight:About 35g (with a
buttony lithium battery)
The Cute Children Pulse Oximeteris registered on the Australian Register of Therapeutic Goods (ARTG)
with the code 136606, and certified by FDA of United States and by CE,TUV of Europe.