Teledyne LeCroy PP011-1, Passive Probe 10 Megaohms, 500 MHz Bandwidth, 400V, 10:1 Attenuation
10:1 Passif 500MHz 51,181po (1300,00mm) Noir Sonde d'oscilloscope fil de test 10M Résistance d'entrée CAT I 400V, CAT II 300V
The PP011 is a miniature high impedance passive probe designed for use with ≥600 MHz Teledyne LeCroy oscilloscopes. Its high input resistance and low capacitance make it ideal for general purpose probing of signals with frequency content from DC through several hundred MHz.
Teledyne LeCroy PP011-1 Offers
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
Teledyne LeCroy PP011-1 Specifications
Bandwidth (Probe Only) 500 MHz
Input Resistance 10 MΩ
Input Capacitance 9.5 pF
Maximum Input Voltage 400 V
Attenuation 10:1
Coupling AC 1 MΩ, DC 1MΩ, GND
Recommended Oscilloscope WaveRunner 6000(A)
WaveRunner Xi(A) ≥ 1 GHz
WaveSurfer Xs(A) ≥ 1 GHz
WavePro 7 Zi, WaveMaster 8 Zi
What's included with the Teledyne LeCroy PP011-1
Passive Probe
PK1-5MM-101 Sprung Hook
PK1-5MM-102 Standard Ground Lead
PK1-5MM-103 Adjustment Tool
PK1-5MM-104 Rigid Tip, 0.8 mm
4 x 2 PK1-5MM-106 Color Coding Rings
PK1-5MM-105 Insulating Cap
Protective Cap
Passive Probes
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
Electrical Characteristics
Bandwidth (Probe Only) 500 MHz
Input Resistance 10 MΩ
Input Capacitance 9.5 pF
Maximum Input Voltage 400 V
Attenuation 10:1
Coupling AC 1 MΩ, DC 1MΩ, GND
Environmental and Safety
Operating Temperature 0 °C to 50 °C
(32 °F to 122 °F)
Humidity 80% Max up to 31 °C
45 % Max at 50 °C
Storage Temperature -40 °C to 71 °C
(-40 °F to 160 °F)
Max Altitude 2000 m
(6562 ft)
Physical Dimensions
Probe Diameter 5 mm
Cable Length 1.2 m
(3.94 ft)
General Characteristics
Interface BNC
Attenuation Sense Pin Yes
Recommended Oscilloscope WaveRunner 6000(A)
WaveRunner Xi(A) ≥ 1 GHz
WaveSurfer Xs(A) ≥ 1 GHz
WavePro 7 Zi
WaveMaster 8 Zi