STC-3000 Thermostat Temperature Humidity Control Thermometer
STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V
Main Instruction:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration;
efrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.
Specification and Size:
Front panel size: 75(L)x34.5(w)(mm)
Mounting size: 71(L)*29(W)(mm)
Product size: 75(L)x34.5(W)x85(D)(mm)
sensor length: Im (include the probe)
Technical Parameters:
Temperature measuring range: 50°C~99°C
Resolution: 0.1°C
Accuracy: +1°C(-50°C~70°C)
sensor error delay: l minute
Power supply: STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V, 50/60Hz
Power consumption: <3w
Sensor: NTC sensor (IPC)
Relay contact capacity: Cool(10A/250VAC); Heat(10A/250VAC)
Ambient temperature: 0°C~60°C
Storage temperature: -30°C~75°C
Relative humidity: 20-85%(No condensate)
Panel instruction
Indicator light status instruction
Indicator light |
Function |
Note |
Cool indicator ligh |
On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay |
Cool、Heat indicator light can not be “on status simultaneously |
Heat indicator ligh |
On: heating starts;Off:heating stops | |
Set indicator ligh |
On:parameter setting status |
|
Key operation instructructiom
1. View parameter method When the controller is working normally, press and release the “▲” button once, Display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds Return to normal temperature display state 2. Set the parameter method3.Repair system data
Operation instruction
Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off” status, press and hold “ ” key for 3s can turn on the controller.
Under the controller normal working status, screen displays the current temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value + difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.
Menu instruction
Code |
Function |
Set range |
Default |
Note |
F1 |
Temperature set value |
-50~99℃ |
10℃ |
|
F2 |
Difference set value |
1~10℃ |
3℃ |
|
F3 |
Compressor delay time |
1~10 minutes |
3 minutes |
|
F4 |
Temperature calibration value |
-10℃~10℃ |
0℃ |
|
F5 |
Fainthearted /Celsius switching |
Set range |
0/1 |
|
Error description
Alarm when sensor error:Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared. Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Safety Regulations: ★Danger: 1. Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay. 2. Dangers: Prohibit connecting the wire terminals without electricity cut-off. ★Warning: Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion. ★Notice: 1. The power supply should conform to the voltage value indicated in the instruction. 2. To avoid the interference, the sensor down-lead and power wire should be kept a distance.
Wiring diagram
Package included:
1x STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V Temperature and Humidity Controller
Shipping Policy Payment Method Returns Policy
Copyright © 2017 DataCaciques
STC-3000 DC 12V/24V AC110-220V Digital Temperature Controller Thermostat Sensor Store CategoriesProduct View
Detail
STC-3000 Thermostat Temperature Humidity Control Thermometer
STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V
Main Instruction:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration;
efrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.
Specification and Size:
Front panel size: 75(L)x34.5(w)(mm)
Mounting size: 71(L)*29(W)(mm)
Product size: 75(L)x34.5(W)x85(D)(mm)
sensor length: Im (include the probe)
Technical Parameters:
Temperature measuring range: 50°C~99°C
Resolution: 0.1°C
Accuracy: +1°C(-50°C~70°C)
sensor error delay: l minute
Power supply: STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V, 50/60Hz
Power consumption: <3w
Sensor: NTC sensor (IPC)
Relay contact capacity: Cool(10A/250VAC); Heat(10A/250VAC)
Ambient temperature: 0°C~60°C
Storage temperature: -30°C~75°C
Relative humidity: 20-85%(No condensate)
Panel instruction
Indicator light status instruction
Indicator light |
Function |
Note |
Cool indicator ligh |
On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay |
Cool、Heat indicator light can not be “on status simultaneously |
Heat indicator ligh |
On: heating starts;Off:heating stops | |
Set indicator ligh |
On:parameter setting status |
|
Key operation instructructiom
1. View parameter method When the controller is working normally, press and release the “▲” button once, Display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds Return to normal temperature display state 2. Set the parameter method3.Repair system data
Operation instruction
Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off” status, press and hold “ ” key for 3s can turn on the controller.
Under the controller normal working status, screen displays the current temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value + difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.
Menu instruction
Code |
Function |
Set range |
Default |
Note |
F1 |
Temperature set value |
-50~99℃ |
10℃ |
|
F2 |
Difference set value |
1~10℃ |
3℃ |
|
F3 |
Compressor delay time |
1~10 minutes |
3 minutes |
|
F4 |
Temperature calibration value |
-10℃~10℃ |
0℃ |
|
F5 |
Fainthearted /Celsius switching |
Set range |
0/1 |
|
Error description
Alarm when sensor error:Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared. Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Safety Regulations: ★Danger: 1. Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay. 2. Dangers: Prohibit connecting the wire terminals without electricity cut-off. ★Warning: Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion. ★Notice: 1. The power supply should conform to the voltage value indicated in the instruction. 2. To avoid the interference, the sensor down-lead and power wire should be kept a distance.
Wiring diagram
Package included:
1x STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V Temperature and Humidity Controller