STC-3000 DC 12V/24V AC110-220V Digital Temperature Controller Thermostat Sensor

EUR 10,81 Achat immédiat, Livraison gratuite, 30-Jour Retours, Garantie client eBay
Vendeur: gogoshopping888 ✉️ (42.334) 95.7%, Lieu où se trouve: ShenZhen, CN, Lieu de livraison: AMERICAS, EUROPE, ASIA, AU, Numéro de l'objet: 265260508087 STC-3000 DC 12V/24V AC110-220V Digital Temperature Controller Thermostat Sensor.

Product View

Detail

 

STC-3000 Thermostat Temperature Humidity Control Thermometer 

 

 

STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V

 

Main Instruction:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration;
efrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.

Specification and Size:
Front panel size: 75(L)x34.5(w)(mm)
Mounting size: 71(L)*29(W)(mm)
Product size: 75(L)x34.5(W)x85(D)(mm)
sensor length: Im (include the probe)

Technical Parameters:
Temperature measuring range: 50°C~99°C
Resolution: 0.1°C
Accuracy: +1°C(-50°C~70°C)
sensor error delay: l minute
Power supply: STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V, 50/60Hz
Power consumption: <3w
Sensor: NTC sensor (IPC)
Relay contact capacity: Cool(10A/250VAC); Heat(10A/250VAC)
Ambient temperature: 0°C~60°C
Storage temperature: -30°C~75°C
Relative humidity: 20-85%(No condensate)

Panel instruction

 

Indicator light status instruction

Indicator light

Function

Note

Cool indicator ligh

On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay

Cool、Heat indicator

light can not be “on

status simultaneously

Heat indicator ligh

On: heating starts;Off:heating stops

Set indicator ligh

On:parameter setting status

 

 

Key operation instructructiom

1. View parameter method When the controller is working normally, press and release the “▲” button once, Display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds Return to normal temperature display state 2. Set the parameter method
When the controller is working normally, press and hold the “S” button for more than 3 seconds to enter the modified parameter mode, “Set The indicator light is on, and the digital tube displays the code "F1" of the first menu item.
Press “▲” or “▼” to scroll up or down the menu item and display the menu code, press “S”
The key displays the parameter setting value of the current menu. Hold down the “S” key and press and hold “▲” or “ the key can be adjusted up or down and the parameter setting value of the current menu is displayed, while holding down "S" and "▲"
The key or “▼” key can quickly up or down and display the parameter settings of the current menu.
After the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.
If there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.
“Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.

 

3.Repair system data
When the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.

 

Operation instruction

Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off”  status, press and hold “ ” key for 3s can turn on the controller.

Under the controller normal working status, screen displays the current temperature value; also the controller can also  switch the working mode between heating and cooling.

Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value +  difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating  equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool  indicator light on, and refrigerating relay disconnects.

System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat”  indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator  light is off, and the heat relay disconnects.

Menu instruction

Code

Function

Set range

Default

Note

F1

Temperature set value

-5099

10

 

F2

Difference set value

110

3

 

F3

Compressor delay time

110 minutes

3 minutes

 

F4

Temperature calibration value

-10℃~10

0

 

F5

Fainthearted /Celsius switching

Set range

0/1

 

Error description

Alarm when sensor error:Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the  running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared. Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function  when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer  alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal  temperature when the error and the fault is cleared.

 

Safety Regulations: ★Danger: 1. Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay. 2. Dangers: Prohibit connecting the wire terminals without electricity cut-off. ★Warning: Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion. ★Notice: 1. The power supply should conform to the voltage value indicated in the instruction. 2. To avoid the interference, the sensor down-lead and power wire should be kept a distance.

 

 

Wiring diagram

 

Package included:

1x STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V Temperature and Humidity Controller 

 

 

 

        

Shipping Policy Payment Method Returns Policy

Copyright © 2017 DataCaciques

STC-3000 DC 12V/24V AC110-220V Digital Temperature Controller Thermostat Sensor Store Categories

Store Categories

Product View

Detail

 

STC-3000 Thermostat Temperature Humidity Control Thermometer 

 

 

STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V

 

Main Instruction:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration;
efrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.

Specification and Size:
Front panel size: 75(L)x34.5(w)(mm)
Mounting size: 71(L)*29(W)(mm)
Product size: 75(L)x34.5(W)x85(D)(mm)
sensor length: Im (include the probe)

Technical Parameters:
Temperature measuring range: 50°C~99°C
Resolution: 0.1°C
Accuracy: +1°C(-50°C~70°C)
sensor error delay: l minute
Power supply: STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V, 50/60Hz
Power consumption: <3w
Sensor: NTC sensor (IPC)
Relay contact capacity: Cool(10A/250VAC); Heat(10A/250VAC)
Ambient temperature: 0°C~60°C
Storage temperature: -30°C~75°C
Relative humidity: 20-85%(No condensate)

Panel instruction

 

Indicator light status instruction

Indicator light

Function

Note

Cool indicator ligh

On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay

Cool、Heat indicator

light can not be “on

status simultaneously

Heat indicator ligh

On: heating starts;Off:heating stops

Set indicator ligh

On:parameter setting status

 

 

Key operation instructructiom

1. View parameter method When the controller is working normally, press and release the “▲” button once, Display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds Return to normal temperature display state 2. Set the parameter method
When the controller is working normally, press and hold the “S” button for more than 3 seconds to enter the modified parameter mode, “Set The indicator light is on, and the digital tube displays the code "F1" of the first menu item.
Press “▲” or “▼” to scroll up or down the menu item and display the menu code, press “S”
The key displays the parameter setting value of the current menu. Hold down the “S” key and press and hold “▲” or “ the key can be adjusted up or down and the parameter setting value of the current menu is displayed, while holding down "S" and "▲"
The key or “▼” key can quickly up or down and display the parameter settings of the current menu.
After the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.
If there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.
“Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.

 

3.Repair system data
When the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.

 

Operation instruction

Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off”  status, press and hold “ ” key for 3s can turn on the controller.

Under the controller normal working status, screen displays the current temperature value; also the controller can also  switch the working mode between heating and cooling.

Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value +  difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating  equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool  indicator light on, and refrigerating relay disconnects.

System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat”  indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator  light is off, and the heat relay disconnects.

Menu instruction

Code

Function

Set range

Default

Note

F1

Temperature set value

-5099

10

 

F2

Difference set value

110

3

 

F3

Compressor delay time

110 minutes

3 minutes

 

F4

Temperature calibration value

-10℃~10

0

 

F5

Fainthearted /Celsius switching

Set range

0/1

 

Error description

Alarm when sensor error:Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the  running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared. Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function  when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer  alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal  temperature when the error and the fault is cleared.

 

Safety Regulations: ★Danger: 1. Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong connections or overloading the relay. 2. Dangers: Prohibit connecting the wire terminals without electricity cut-off. ★Warning: Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion. ★Notice: 1. The power supply should conform to the voltage value indicated in the instruction. 2. To avoid the interference, the sensor down-lead and power wire should be kept a distance.

 

 

Wiring diagram

 

Package included:

1x STC-3000 DC 12V/STC-3000 DC 24V/STC-3000 AC 110-220V Temperature and Humidity Controller 

 

 

 

        

Shipping Policy Payment Method Returns Policy


Le 04-janv.-22 à 11:56:10 Paris, le vendeur a ajouté les informations suivantes :

  • Condition: Neuf
  • Voltage: DC 12V
  • Marque: - Sans marque/Générique -
  • Brand: Unbranded
  • Type: Thermostat Sensor

PicClick Insights - STC-3000 DC 12V/24V AC110-220V Digital Temperature Controller Thermostat Sensor PicClick Exclusif

  •  Popularité - 8 personnes suivent la vente, 0.0 de nouvelles personnes suivent la vente par jour, 963 days for sale on eBay. Super grande quantité suivi. 4 vendu, 10 disponibles.
  •  Meilleur Prix -
  •  Vendeur - 42.334+ articles vendu. 4.3% évaluations négative. Bon vendeur avec bonne rétroaction positive et bonne quantité de cotes.

Les Gens ont Aussi Aimé PicClick Exclusif